Exile X2400.1 User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 38
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
18
DOT SIZE TEST
This test is similar to the Contrast Test, except that the image is of mesh pattern, with
each square representing a 2x2 dot. The plot length is also selectable from 1” to 48”. A
microscope or a magnifying lens may be used to examine the mesh patterns. This test
may provide a guideline to selecting the appropriate contrast setting for those application
images with demanding resolution requirement.
NIB R PLOT
This test prints out the stored nib reistance data.
NIB R MEASUREMENT
This test performs the nib resistance measurement using the onboard circuitry and stores
the result in the onboard nonvolatile memory. The test data and result may be viewed by
using NIB R PLOT.
== Contrast: -30% ==
== Contrast: -25% ==
== Contrast: -35% ==
Avg -2.5%= 5575 Ohms
Avg = 5717 Ohms Rmax = 5795 Rmin = 5661 #out-of-range (+/-2.5%) = 0
Avg +2.5%= 5895 Ohms
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 37 38

Comments to this Manuals

No comments