Table 3 - ITEMS of JOB MENU
ITEM PARAMETER DEFINITION
Imager Resolution - H: 600 dpi V: 600 dpi
- H: 600 dpi V: 1200 dpi
- H: 600 dpi V: 2400 dpi
H (horizontal):
along the print head
V (vertical):
the direction of media movement.
Automatic Media Cut - No
- Yes
Cut the media after receiving EOT
Closed-loop Control - No
- Yes: Absolute mode
- Yes: Overlap mode
Turn off or on the closed-loop control
of platen accuracy adjustment (Note 1)
Notes:
1. In the Closed-loop control: absolute mode, the movement of media is adjusted such that
each image output be brought to within a precision spec (against an accuracy ruler). In
the Closed-loop on: overlap mode, the control emphasis is on the overlap accuracy of
consecutive outputs (of the same image).
Table 4 - ITEMS of IMAGE MENU
ITEM PARAMETER DEFINITION
Contrast Level -35% to +20%
(5% increment)
Adjust image contrast level
Show Transport Parm - No
- Yes
Display transport parameters for debugging
usage in Platen Accuracy Test and after FF
or EOT during on-line imaging
Page view 22