4.4 Guideline for Selecting Contrast Setting
Note that the use of inappropriate contrast setting for a specific media may void the
warranty on the print head. In order to achieve best image result as well as to prolong the
life of print head, the following guideline may be referred:
In the Contrast Test, an optical densitometer may be used to measure the optical
density (o.d.) of the plot at each contrast setting, and a comparison of o.d. at all the
settings can be made. Usually the curve of o.d. has a steep rising slope as the contrast
setting increases. Then it reaches the saturation point and either slides down or stays
almost flat. The setting at the saturation point would be the best choice.
5.0 ERROR MESSAGES
The following Error Messages may appear on the VF Display. There are three categories
of error messages. The error messages along with their cause and remedy are listed
below.
5.1 Errors Due to Inappropriate System Configuration
"No plotter connector"
Cause: The print head connector is not plugged in.
Remedy: Turn off the TechSetter and plug in the connector.
"The lid is open!"
Cause: The top section is not completely latched.
Remedy: Close and latch the top section. Then reset the system by either
pressing the reset button or turning the system off and on.
5.2 Errors Occurred During Plotting Operation
"Out of media!"
Cause: Media runs out.
Remedy: Load a new roll of media.
"Thermohead overheat!"
Cause: The print head is overheated.
Remedy: Turn off the TechSetter immediately. Wait for the print head to
cool down before restarting. If the overheating problem persists,
please consult the technical support.